1. IE browser is NOT supported anymore. Please use Chrome, Firefox or Edge instead.
2. If you are a new user, please register to get an IHEP SSO account through https://login.ihep.ac.cn/registlight.jsp Any questions, please email us at helpdesk@ihep.ac.cn or call 88236855.
3. If you need to create a conference in the "Conferences, Workshops and Events" zone, please email us at helpdesk@ihep.ac.cn.
4. The max file size allowed for upload is 100 Mb.
15–16 Aug 2012
四川绵阳豪瑞特酒店
Asia/Shanghai timezone

二维位置灵敏闪烁体中子探测器的模拟研究

16 Aug 2012, 08:40
10m
5F豪瑞多功能厅 (四川绵阳豪瑞特酒店)

5F豪瑞多功能厅

四川绵阳豪瑞特酒店

四川省绵阳市涪城区会仙路16号

Speaker

Mr 振 杨 (epc)

Description

摘要:中国散裂中子源工程已于2011年10月破土动工,闪烁体中子探测器作为可替代3He气体的中子探测器,目前成为国际上的研究热点。本文基于GEANT4蒙特卡罗模拟平台,构建了二维位置灵敏型6LiF/ZnS(Ag)闪烁体中子探测器模型,对探测器的关键性能进行了系统的模拟研究。模拟结果表明,当采用双层闪烁屏中间夹二维波移光纤阵列的“三明治”式探测器结构时,其热中子探测效率可达49.1%;模拟和实验也展现了探测器良好的n/γ抑制能力,γ灵敏度可达小于10-5;中子位置分辨率随着光纤芯间距和光纤与闪烁屏距离的减小而减小,其本征空间分辨率最好可达0.08mm(X方向)和0.12mm(Y方向);模拟结果也表明探测器具有良好的二维成像能力。该研究工作为中国散裂中子源闪烁体型位置灵敏中子探测器的设计和优化提供了可靠的参考数据。 关键词:GEANT4;6LiF/ZnS(Ag)闪烁体;热中子探测;波移光纤 The Simulation on Two-dimensional position sensitive scintillation neutron Detector Yang Zhen1,2 Zhang Qiang1,2,3 Tang Bin1,2 Sun Zhi-jia1,2 Yang Gui-an1,2 Zhou Jian-rong1,2 Xu Hong1,2 Wang Tuo1,2,3 1. State Key Laboratory of Particle Detection and Electronics (Institute of High Energy Physics, CAS and University of Science and Technology of China) 2. Institute of High Energy Physics CAS 3. China University Of Petroleum Beijing Abstract: Chinese Spallation Neutron Source(CSNS) project has started since October 2011, As substitute of 3He gas detector, scintillator neutron detector has been a research focus internationally. In this paper, a module of position sensitive neutron detector based on 6LiF/ZnS(Ag) scintillator was constructed by GEANT4 package, and its key properties were studied. The simulation results show that the thermal neutron detection efficiency could reach 49.1% when “sandwich structure” of detector was set. Both simulation and experimental result reveal its good ability of n/γ rejection ration, and the gamma sensitive could be less than 10-5. The smaller of the distance between each WLSF, and the gap between the WLSFs array and scintillator are, the better the position resolution is. The intrinsic spatial resolution is 0.08mm for X-axis and 0.12mm for Y-axis. The simulation results and that of parts experimental results plot the detector have a good 2D imaging capability. Work above can provide reliable data for scintillation neutron detector in CSNS. Key words:GEANT4; 6LiF/ZnS(Ag) scintillator; thermal Neutron detection; Wave Length Shifting Fiber

Primary author

Mr 振 杨 (epc)

Presentation materials

There are no materials yet.