Neutrino Geoscience 2026, Zhuhai, China, 17 November 2026
Atmospheric neutrinos add a third view of the deep Earth
Seismic waves
Elastic properties
Wave speeds give density through mineral physics and gravity constraints. Composition stays indirect.
Geoneutrinos
Radiogenic sources
MeV νˉe from U and Th decay measure the heat-producing budget.
Atmospheric neutrinos
Nucleons and electrons
Absorption at TeV–PeV counts nucleons. Oscillations at GeV count electrons. Both come from weak interactions alone.
Oscillations see only the electron density: Ne=ρmNZ/A
ρ
Z/A
What is measured
Oscillation parameters
PREM
assumed
θij, Δm2, ordering
Density tomography
fitted
assumed
ρ per layer
Composition
PREM
fitted
Z/A per layer
Neutrinos only
from absorption
fitted
Z/A, limited by ρ to tens of %
Cosmic rays make neutrinos in the atmosphere
Cosmic rays, mostly protons, hit the atmosphere everywhere, all the time.
The collisions make pions, which decay into muons and muon neutrinos.
The muons decay into electrons and more neutrinos.
About two νμ for every νe, from every direction.
Illustration, not to scale. Colours: νμ, νe.
Neutrinos from below cross the Earth and change flavour
Up to 12 700 km through the planet.
On the way, the flavour changes: neutrino oscillations.
Illustration, not to scale; vacuum oscillations only. Colours: νμ, νe, ντ.
KM3NeT: one technology, two detectors in the Mediterranean
ORCA
ARCA
Site
Toulon, France
Capo Passero, Italy
Depth
2470 m
3500 m
ORCA
ARCA
Building blocks
1 dense
2 sparse
String spacing
20 m
90 m
Vertical spacing
9 m
36 m
Energy
1–100 GeV
> 1 TeV
Each line carries 18 optical modules with 31 3″ PMTs.
Cherenkov light: the medium polarises, then relaxes
Slower than light in water
Molecules polarise symmetrically around the particle. Their emission cancels: no light.
Faster than light in water
The polarisation lags behind the particle. The wavelets add up on a cone.
cosθC=nβ1
θC≈42° in sea water (n≈1.35).
Yellow: nuclei; blue: electron clouds. Illustration after J. V. Jelley, Čerenkov Radiation and its Applications (1958). Not to scale.
Cherenkov light tells us flavour, energy and direction
Track: νμ CC
The muon gives a long lever arm for direction.
Direction: < 0.4° at 10 TeV (ARCA), ~7° at 10 GeV (ORCA) Energy: ~30–35 %
Shower: νe CC and NC
A compact light source gives a better energy estimate.
Direction: < 1° at 30 TeV (ARCA), ~7° at 10 GeV (ORCA) Energy: ~5 % (ARCA), ~25 % (ORCA)
Illustration of the detection principle, not simulated data. Performance: PoS(ICRC2021)1077, 1089; arXiv:1612.05621.
Construction is advancing: 44 ORCA and 62 ARCA lines installed
0 of 108
ORCA lines installed
Completion around 2030
0 of 230
ARCA lines installed
Completion around 2032
Exposure by November 2025: 3.24 Mton-yr for ORCA and 279 Mton-yr for ARCA.
Line maps: KM3NeT Collaboration, November 2026. Completion dates: report to the IN2P3 Scientific Council, February 2026.
Atmospheric neutrinos: a free beam across every baseline
ORCA
ARCA
ORCA, GeV
Oscillations in matter, sensitive to Ne.
About 30 000 events per year with the full detector (10 000 tracks, 20 000 showers).
ARCA, TeV–PeV
Absorption, sensitive to ρ.
About 80 000 events per year with the full detector (60 000 tracks, 20 000 showers).
Rates: L. Maderer, PhD thesis (2022), Figs. 8.2 and 9.2.
What sets the oscillation of a neutrino crossing the Earth
P(νμ→νμ)≃1−sin22θ23sin2(1.27EΔm312L)
Neutrino properties
Mixing angles θ12,θ13,θ23, phase δCP, mass splittings Δm212,Δm312 and the mass ordering. Measured by many experiments, ORCA included.
Path and energy
Path length L fixed by the arrival direction; energy E of 1–100 GeV for ORCA.
The Earth
Electron density along the path, Ne=ρ(Z/A)/mN: PREM gives ρ. Matter modifies the formula above; this is what tomography measures.
Vacuum, two flavours, with ~10 % energy smearing. A longer path moves the dip to higher energy; fast oscillations at low energy average out.
Live calculation with sin22θ23=1, Δm312=2.5×10−3 eV²; matter effects on the next slides.
Below ~15 GeV, matter acts on one flavour and resonance appears
Only νe scatter coherently on electrons:
V=±2GFNe
Mixing becomes maximal at
Eres=22GFNeΔm312cos2θ13
With Z/A≈0.5, this gives ~7 GeV in the mantle and ~3 GeV in the core.
The sign of V flips for antineutrinos, so the resonance is in ν for normal ordering and in νˉ for inverted ordering.
Live two-flavour constant-density calculation with Δm312=2.5×10−3eV2, θ13=8.6°, Z/A=0.495.
Arrival direction selects the layers a neutrino has crossed
PREM, Dziewonski and Anderson (1981). Live calculation, detector at the surface.
Above ~10 TeV, the Earth's neutrino shadow maps its mass
P(E,θz)=exp[−mNσνN(E)∫0L(θz)ρ(x)dx]
Live calculation: PREM, ν only, CC + NC cross section from Cooper-Sarkar, Mertsch and Sarkar, JHEP 08 (2011) 042; no regeneration. Illustrative, no detector.
Absorption is incoherent: neutrinos hit single nucleons
Coherent
Incoherent
Process
Forward scattering on all electrons
Deep-inelastic scattering on one nucleon
Effect
Shifts the oscillation phase
Removes or degrades neutrinos
Energy
GeV (ORCA)
TeV–PeV (ARCA)
Measures
Ne
Nnucleon∝ρ
λint=NnucleonσνN(E)1
Equal to the Earth's diameter near 40 TeV.
Plus the Glashow resonance, νˉee−→W− at 6.3 PeV, on electrons.
C. A. Argüelles, J. Salvado, C. N. Weaver, nuSQuIDS, Comput. Phys. Commun. 277 (2022) 108346, arXiv:2112.13804.
ARCA sees the difference between coarse and fine Earth models
TracksShowers
PREM with 42 and 5 layers
χsigned2=sign(ΔN)N(ΔN)2
ΔN=N42−N5
Per bin of energy and direction: red means more events with 42 layers, blue fewer; the intensity is how much the bin contributes. The sum is the total Δχ2.
Most of the sensitivity comes from 1–100 TeV.
Tracks give ~95 % of it.
Signed χ2 between the two models, ARCA 2 building blocks, 10 years, statistics only: total 1.67, falling to 0.59 with the MC error. L. Maderer, PhD thesis (2022).
Turning on the Earth reshapes the oscillation pattern
P(νμ→νe)
P(νμ→νμ)
Next: animate from vacuum to full PREM.
Below the core line the pattern changes abruptly: the core is a distinct oscillation medium.
This talk: 3-flavour evolution in PREM, normal ordering, NuFIT 6.0 best-fit mixing (IC24 + SK-atm), Z/A=0.469 core, 0.495 mantle. True energy and direction, no detector.
Mass ordering decides where that signal lives
Normal ordering, ν
Normal ordering, νˉ
Inverted ordering, ν
Inverted ordering, νˉ
Water Cherenkov detectors do not separate ν from νˉ. Flux and cross section favour ν, so inverted ordering weakens tomography.
This talk: same calculation as the previous slide, P(νμ→νe), IO values from NuFIT 6.0.
Detector resolution washes out the finest structure
Reconstructed events keep the mantle resonance region, while fast oscillations average out.
The challenge is energy and direction at 3–10 GeV, where the scattering angle itself limits resolution.
Full ORCA, 3 years, all detector effects, PREM. KM3NeT simulation.
ORCA can fit the density layer by layer, in simulation
The Earth is cut into five layers of constant density. Black: PREM, used to make the pseudo-data.
Blue: free fit, neutrinos only. Green: Earth's mass and moment of inertia fixed to their known values.
The fit gets PREM back, to a few % in the mantle and ~10–30 % in the core.
Earth's mass to 6.5 %, against ~25 % with ARCA absorption.
Full ORCA, 10 years, simulation, no systematics, Z/A fixed. L. Maderer, PhD thesis (2022), Fig. 9.7; bands are 68 % posterior.
Reading it the other way, oscillations measure composition
Ne=mNρAZ
Fix ρ from seismology and Z/A follows.
Pure iron core: 0.466 Light-element core models: up to 0.472 Pyrolitic mantle: 0.496
Core models differ by only ~1 % in Z/A.
ORCA, 10 years
1σ on Z/A: 5 % in the mantle, 6 % in the outer core, assuming normal ordering.
Change in P(νμ→νe)
Orange: more νe. Blue: fewer. Scale ±0.12.
Centre: this talk, relative to Z/A=0.469 (values: I. Goos et al., Earth Planet. Sci. Lett. 696 (2026) 120354). Right and numbers: S. Bourret for KM3NeT, EPJ Web Conf. 207 (2019) 04008, systematics included. Z/A values: C. Rott et al., Sci. Rep. 5 (2015) 15225.
The way forward is a joint inversion with seismology
Forward model
Oscillations and absorption through an Earth model
Fréchet derivatives
Linearise the problem; one set per detector
Joint inversion
One large matrix with the seismic data, inverted and applied to data
Earth model
ρ(r) and Z/A(r)
Oscillation observables are orthogonal to seismic ones: together they can disentangle what seismology alone leaves open.
The sensitivity of an ideal detector peaks in the outer core at 3–4 GeV and in the mantle near 7 GeV.
Every detector adds its own derivatives: the more detectors take part, the better.
I. Goos et al., Earth Planet. Sci. Lett. 696 (2026) 120354: 1D, no systematics, ORCA benchmark of 160 Mton-yr in 20 years. Geoscience–neutrino work, not a KM3NeT Collaboration result.
Neutrinos look at the Earth differently from earthquakes
Left, seismology: one earthquake, many stations, signal versus time. Right, neutrinos: one detector, sources all around the sky, signal versus energy and direction.
Where a +1 % change in ne in one 100 km shell shows up
Ideal detector: the outer core. ORCA: the lower mantle, whose ~7 GeV resonance it resolves better.
Small numbers: one isolated shell is a lower bound, since mass, moment of inertia and hydrostatic equilibrium are not re-imposed.
Original figures: I. A. Goos et al., Earth Planet. Sci. Lett. 696 (2026) 120354, Figs. 1 (a–d) and 9 (CC BY 4.0). 1D, no systematics. Not a KM3NeT Collaboration result.
ORCA's new oscillation measurement uses 1.4 Mton-yr
Moderate tension with world data on the mass splitting
KM3NeT Preliminary, 1.4 Mton-yr. Earlier measurements in backup.
No single systematic moves the result by more than 0.2σ
Cross section and detector modelling lead
Top terms: resonant and NC cross sections, energy scale, trigger; Sτ for Δm312.
Flux: Honda preferred
Δχ2=3.6 over a DaemonFlux-based hybrid (p = 0.49 against 0.01). That model is not yet tuned for the ORCA site.
Run periods agree within 2σ
ORCA11-18 alone prefers a higher Δm322 than ORCA6-7, and NO over IO.
KM3NeT Preliminary, 1.4 Mton-yr. Pulls and flux tests in backup.
Full ORCA reaches 4.4σ on the ordering in 3 years if normal
Against data-taking time: 2.3σ at 3 years if invertedSensitivity against θ23, 3 years
The answer depends strongly on θ23, so the octant matters as much as the exposure.
KM3NeT Collaboration, Eur. Phys. J. C 82 (2022) 26, arXiv:2103.09885. Complete detector of 115 lines from day one, NuFIT 4.1 parameters, 68 % sensitivity bands.
Summary
Absorption with ARCA
An independent weak-interaction measure of mass density, at tens of percent per layer after 10 years.
Oscillation tomography with ORCA
Electron density and Z/A: ~5–6 % in 10 years, for normal ordering.
Oscillation program
ORCA measures oscillations at 1.4 Mton-yr. The mass ordering comes next.
Everything here uses atmospheric neutrinos, a free beam through the whole Earth. All tomography numbers are sensitivity studies. With 44 ORCA lines installed, the data to test them are arriving.
Backup
One simulation chain serves absorption and oscillation tomography
Full ARCA, 2 building blocks: ~60 000 tracks and ~20 000 showers per year.
L. Maderer, PhD thesis (2022).
ARCA's 10-year density fit, compared with IceCube
Full ARCA simulation, 10 yearsIceCube, 1 year of data and 10-year forecast (red)
Similar in the middle layers. IceCube's forecast is tighter in the inner core and outer mantle.
Left: L. Maderer, PhD thesis (2022), no systematics, with and without MC error. Right: A. Donini et al., Nature Phys. 15 (2019) 37.
ORCA performance, full detector
arXiv:1612.05621.
ARCA performance, full detector
PoS(ICRC2021)1077 and 1089.
ORCA projections: ντ and atmospheric parameters
Three years of full ORCA, normal ordering, NuFIT 4.1, arXiv:2103.09885.
Contours in the (ρ, Z/A) plane
KM3NeT Preliminary. L. Maderer et al., PoS(ICRC2021)1172.
Mass-ordering test with 1.4 Mton-yr
Lower octant, θ23=40°Upper octant, θ23=50°
KM3NeT Preliminary.
ORCA combined with JUNO and Daya Bay
ORCA6–18, 1.4 Mton-yr: IO p = 0.013 (2.5σ)ORCA11-18, 0.84 Mton-yr: IO p = 0.093 (1.7σ)
KM3NeT Preliminary, θ23=43.29° (NuFIT 6.1, NO).
Nuisance-parameter pulls at 1.4 Mton-yr
KM3NeT Preliminary.
Atmospheric flux model test
Honda p = 0.49, HybridFlux p = 0.01Flux ratios to HKKMS15 at Fréjus
KM3NeT Preliminary. HybridFlux: South Pole, no geomagnetic effects, large low-energy difference from Honda.
Earlier ORCA measurements
433 kton-yr: 5828 neutrino candidates. Inverted ordering disfavoured with p = 0.25. 715 kton-yr (Bayesian, preliminary): no significant ordering preference, Bayes factor 1.18.