    • 09:00 09:20
      Status and plan 20m
      Speaker: Dr Yong Liu (Institute of High Energy Physics)
      Slides

      https://jupyter.ihep.ac.cn/dmnuk8tsQTCeBUpOg9SIOA?both

      Saved at 11:37, 2020.09.02

      CEPC Calorimeter Software Meeting
      2020.09.02
      召集人:伍灵慧
      参会人员:刘勇,刘春秀,李刚,李波,方文兴,孙胜森,王悦心,郭方毅,傅成栋,伍灵慧
      indico page: https://indico.ihep.ac.cn/event/12439/

      工作内容:集中力量验证reference detector方案,给出初步结果

      Minutes: Linghui, Yong

      • Current status of crystal ECAL simulation studies: Yong

        • ECAL detector layout
          • Long crystal bars with double-ended readout
          • Crossed placement in alternating layers
        • Geant4 stand alone simulation
          • Digitiser for crystal cubes and scintillator tiles (done)
          • Digitiser for long crystal bars, esp. timing at two ends (done, but needs further validation)
        • CEPCsoft
          • Implemented two layouts of crystal ECAL geometry: long bars, cubes
          • Event display with “Druid”
        • CEPCSW
          • Basic sub-detectors already implemented in DD4HEP
      • Discussions on the efforts/plans for CEPCSW: Bo, Gang, Linghui, Shengsen, Yong, Yuexin

        • ECAL geometry: first priority
          • Implementation of crystal ECAL with long bars
        • Studies of a single long crystal bar
          • Basis for digitisation; needs solid validation
          • Full simulation in Geant4 with optical photon processes
          • Develop test stands and perform measurements for comparision with the full simulation
        • Multi-hits
          • in a single crystal bar
          • To be checked
        • Digitization: needs further discussions
          • Energy
          • Timing
        • PFA performance
          • Dependency on the tracker performance
          • Matching performance of charged tracks in the tracker and ECAL
          • Energy information for PFA
            • Software compensensation
            • Dual readout for crystals
          • PandoraPFA
            • Tuning of calibration constants
            • Validation with MC truth
        • Calibration studies for CEPC calorimeters (Stathes’ proposal)
          • To prepare MC samples and provide information that he needs
          • Need further detailed discussions: Yong, Hongbo, Stathes
      • Action items

        • G4 full simulation of a long crystal bar: Baohua, Yong (1~2 weeks)
        • Preparation of test stands for crystals: Baohua, Yong (~4 weeks)