1. IE browser is NOT supported anymore. Please use Chrome, Firefox or Edge instead.
2. If you are a new user, please register to get an IHEP SSO account through https://login.ihep.ac.cn/registlight.jsp Any questions, please email us at helpdesk@ihep.ac.cn or call 88236855.
3. If you need to create a conference in the "Conferences, Workshops and Events" zone, please email us at helpdesk@ihep.ac.cn.
4. The max file size allowed for upload is 100 Mb.
21–26 Oct 2026
Sheraton Shanghai Jiading Hotel
Asia/Shanghai timezone

Development and Characterization of a Compact Silicon Micro-strip Tracking System

Not scheduled
20m
3rd Floor Hallway

3rd Floor Hallway

Poster Presentation 07: Silicon Detectors Posters

Speaker

Mr Yiyang Pan (高能物理研究所)

Description

Silicon microstrip detectors provide high spatial resolution, reliable charge measurement, and a scalable detector architecture, making them well suited for charged-particle tracking, beam monitoring, and detector prototyping. In this work, we present the development and initial characterization of a compact silicon microstrip tracking system based on p-on-n strip sensors. Each detector module has 192 readout channels and an effective sensitive area of approximately 26*40 mm^2. The sensor is integrated with three 64-channel IDE1140 front-end ASICs, dedicated bias and control circuits, and a compact mechanical support structure. The system is designed to accommodate six modules arranged in three tracking stations with orthogonal strip orientations, enabling two-dimensional hit reconstruction and particle-track measurement.

The data acquisition system is built around a Xilinx ZCU102 FPGA board with dedicated firmware and control software. It supports front-end configuration, online calibration, programmable sampling delay, pedestal and noise measurements, and data acquisition using either internal or external triggers. Individual detector modules have been commissioned under a bias voltage of 50 V. The measured channel noise is typically around two ADC counts. Cosmic-ray measurements have been performed with several modules, and clear particle-induced cluster signals have been observed. A scan of the sampling delay also demonstrates its significant influence on the collected signal amplitude and detection efficiency.

The system is being integrated with a previously developed track-reconstruction framework. Together with our experience in operating an silicon beam monitor at the High Energy Photon Source, this development establishes a technical basis for compact beam telescopes and beam-diagnostic systems. Potential applications include charged-particle beam monitoring, characterization of novel detector prototypes, and tracking references for future high-energy physics experiments. The poster will present the detector design, DAQ architecture, cosmic-ray results, and the roadmap toward synchronized multi-module operation and beam tests.

Primary authors

Zijun 子骏 Xu 徐 刘 康 (IHEP) Mr Yiyang Pan (高能物理研究所)

Presentation materials

There are no materials yet.