21–26 May 2017
Beijing International Convention Center
Asia/Shanghai timezone

Session

R2-Gaseous detectors(3)

25 May 2017, 09:00
Beijing International Convention Center

Beijing International Convention Center

No.8 Beichen Dong Road, Chaoyang District, Beijing P. R. China 100101

Conveners

R2-Gaseous detectors(3)

  • Bo Yu (Brookhaven National Lab)
  • Jianbei Liu (University of Science and Technology of China)

Presentation materials

There are no materials yet.

  1. Tomomi Kawaguchi (Nagoya University)
    25/05/2017, 09:00
    Gaseous detectors
    oral
    The High-Luminosity LHC (HL-LHC) is planned to start the operation in 2026 with an instantaneous luminosity of 7.5 x 10^34 cm-2s-1. To cope with the event rate higher than that of LHC, the trigger and readout electronics of ATLAS Thin Gap Chamber will need to be replaced. An advanced first-level trigger with fast tracking will be implemented with the transfer of all hit data from the frontend...
    Go to contribution page
  2. Chengguang Zhu (Shandong University)
    25/05/2017, 09:18
    Gaseous detectors
    oral
    The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five to seven with respect to the design value by undergoing an extensive upgrade program over the coming decade. Such increase will allow for precise measurements of Higgs boson properties and extend the search for new physics phenomena beyond the Standard Model. The largest phase-1 upgrade...
    Go to contribution page
  3. Dr Huirong Qi (Institute of High Energy Physics, CAS)
    25/05/2017, 09:36
    Gaseous detectors
    oral
    Compared with the International Linear Collider (ILC), the beam structure of the future Circular Electron Positron Collider (CEPC) is very different without the ‘power-pulsing’ mode. In this paper, some simulation and estimation results of the Time Projection Chamber (TPC) as one tracker detector option for CEPC were given. The optimized operation gas (Ar:CF4:C2H6=92:7:1) with the fast...
    Go to contribution page
  4. Igal Jaegle (BEAST II Collaboration - University of Florida)
    25/05/2017, 09:54
    Gaseous detectors
    oral
    Ten 10 cm drift distance Time Projection Chambers (TPCs), filled with He:CO2:70:30 at slightly above one Atmosphere, equipped with a double GEM and a high resolution pixel readout were built by the University of Hawaii to measure fast neutrons produced by the SuperKEKB beam-induced background during the first and second commissioning phases. We characterized the TPCs with two different sources...
    Go to contribution page
  5. Prof. Ke Han (Shanghai Jiao Tong University)
    25/05/2017, 10:12
    Gaseous detectors
    oral
    The PandaX-III (Particle And Astrophysical Xenon Experiment III) experiment will search for Neutrinoless Double Beta Decay (NLDBD) of Xe-136 at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% Xe-136 enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk...
    Go to contribution page