1. IE browser is NOT supported anymore. Please use Chrome, Firefox or Edge instead.
2. If you are a new user, please register to get an IHEP SSO account through https://login.ihep.ac.cn/registlight.jsp Any questions, please email us at helpdesk@ihep.ac.cn or call 88236855.
3. If you need to create a conference in the "Conferences, Workshops and Events" zone, please email us at helpdesk@ihep.ac.cn.
4. The max file size allowed for upload is 100 Mb.

BAMS: a new compact 14C AMS system at CEDAD (Centre of Applied Physics, Dating and Diagnostics), University of Salento for biomedical and pharmaceutical research

PSB-44
23 Oct 2024, 17:55
20m
Lobby and Hallway , 2nd Floor

Lobby and Hallway , 2nd Floor

Poster New and Upgraded Facilities Poster Session B

Speaker

Gianluca Quarta (University of Salento)

Description

In the frame of the PRP (Pathogen Readiness Platform) project funded through the post-pandemic Italian plan for recovery and resilience (PNRR: Piano Nazionale Ripresa e Resilienza) the installation of a new compact Accelerator Mass Spectrometry system is planned at CEDAD (Centre of Applied Physics, Dating and Diagnostics), Department of Mathematics and Physics “Ennio de Giorgi”, University of Salento. The new system is expected to provide an essential asset for drug-development by Biomedical Accelerator Mass Spectrometry (BAMS) which will be adopted as a powerful bio-analytical method for human studies in the areas of pharmacology and toxicology. The new system will assist classic DMPK (Drug Metabolism and Pharmacokinetics) studies where 14C is used as a tracer in drug development for evaluating the distribution and binding of novel drug candidates allowing the use of low-level drug doses. Microdosing and microtracing will result in a more cost and time effective drug development pipeline. For this application the main requested features for the AMS system are: 14C sensitivity at least in the 10-15 range (14C/12C ratio), uncertainty better than 0.3% and 0.5 % for solid and gas samples, respectively and high sample throughput.
The new set-up will be formed by a new dedicated 14C AMS system manufactured by High Voltage Engineering Europa Mod. HVEE 4102Bo operated at a terminal voltage of 210 kV. The system is based on a multicathode S-110C hybrid ion source capable of accepting both solid and gas samples handled by a dedicated gas interface. The tandem accelerator is operated by a vacuum insulated power supply, incorporated into the vacuum vessel and operating at a maximum terminal voltage of 210 kV. The system is equipped with permanent magnets ensuring reduced power consumption (2.5 kW) and is equipped with a dedicated system for automatic tuning and data analysis. The reduced footprint of the machine (approximately 3 x 2.8 m) will allow its installation in the hall where the Tandetron accelerator (HVEE Mod. 4130HC) is installed and in operation.
The general features of the system are presented as well as preliminary results obtained during preliminary tests and future projects.

Student Submission No

Primary authors

Dr Dalila Peccarrisi (CEDAD-Dept. of Mathematics and Physics, University of Salento) Prof. Lucio Calcagnile (CEDAD-Dept. of Mathematics and Physics, University of Salento) Gianluca Quarta (University of Salento) Dr Giorgio Carbone (CEDAD-Dept. of Mathematics and Physics, University of Salento) Dr Lucio Maruccio (CEDAD-Dept. of Mathematics and Physics, University of Salento) Dr Marisa D'Elia (CEDAD-Dept. of Mathematics and Physics, University of Salento) Dr Mattia Fragola (CEDAD-Dept. of Mathematics and Physics, University of Salento)

Presentation materials

There are no materials yet.