1. IE browser is NOT supported anymore. Please use Chrome, Firefox or Edge instead.
2. If you are a new user, please register to get an IHEP SSO account through https://login.ihep.ac.cn/registlight.jsp Any questions, please email us at helpdesk@ihep.ac.cn or call 88236855.
3. If you need to create a conference in the "Conferences, Workshops and Events" zone, please email us at helpdesk@ihep.ac.cn.
4. The max file size allowed for upload is 100 Mb.

Positron Detection System of Muonium-to-Antimuonium Conversion Experiment

Not scheduled
4m
Rare Decays Poster Session

Speaker

UNKNOWN 彭华兴

Description

The Muonium-to-Antimuonium Conversion Experiment (MACE) aims to investigate charged lepton flavor violation (cLFV) through investigating spontaneous muonium-to-antimuonium conversion. This process is detected using a positron detection system (PDS), which consists of a lead-free microchannel plate (MCP) and a BGO electromagnetic calorimeter (ECal). In this study, we conducted preliminary prototype experiments to evaluate the performance of the PDS. Using photomultiplier tubes (PMTs) coupled with BGO scintillation crystals, we measured the detector's time resolution, achieving a value of approximately 2.6 ns. Additionally, utilizing a positron beam at the Institute of High Energy Physics (IHEP), we determined the detection efficiency of the lead-free MCP for positrons in the energy range of 300 eV to 1200 eV, obtaining an efficiency about 30%. These results demonstrate the feasibility of the PDS for the MACE and provide critical insights into its operational performance.

Primary author

Presentation materials

There are no materials yet.