CEPC Calorimeter Weekly Meeting on TDR
→
Asia/Shanghai
Jianbei Liu
(University of Science and Technology of China),
Yong Liu
(Institute of High Energy Physics)
Description
Zoom connection information
-
Meeting ID: 666 4623 8623
-
Passcode: cepc-tdr
-
-
1
Introduction and newsSpeakers: Jianbei Liu (University of Science and Technology of China), Dr Yong Liu (Institute of High Energy Physics)
-
Electronics, mechanics, physics and software: discussions on CEPC-TDRConveners: Jinfan Chang (高能所), Manqi Ruan (IHEP), Shaojing 侯少静 (高能所), Sheng-Sen Sun (Institute of High Energy Physics)
-
2
Calorimeter electronicsSpeaker: Jinfan Chang (高能所)
Electronics: clarify requirements for inputs
- Considerations start from data transfer: back-end electronics
- Data throughput
- Front-end ASIC: (1) waveform sampling? or (2) Q-T only?
- Cost estimates
- 1-ch vs multi-ch ASIC
- Need anything from the Electronics Team to help option down select?
- Formulate Common requirements: e.g. waveform sampling (vs. data transmission speed)
- Better to have a list of specs to the Electronics Team
- Considerations start from data transfer: back-end electronics
-
3
Calorimeter mechanicsSpeakers: Quan JI, Shaojing 侯少静 (高能所)
-
4
Calorimeter softwareSpeakers: Fangyi Guo, Sheng-Sen Sun (Institute of High Energy Physics)
-
5
Physics performance related to calorimetersSpeaker: Manqi Ruan (IHEP)
-
2
-
CEPC calorimeter options: down select for CEPC-TDRConvener: Jianbei Liu (University of Science and Technology of China)
-
6
Plastic scintillator ECAL and HCALSpeaker: Yunlong Zhang (University of Science and Technology of China)
-
7
Silicon ECAL and glass-RPC HCALSpeaker: Haijun Yang (Shanghai Jiao Tong University)
-
8
Crystal and glass ECALSpeakers: Huaqiao ZHANG (IHEP), Dr Yong Liu (Institute of High Energy Physics)
-
9
Glass HCALSpeakers: Peng Hu (IHEP), Sen Qian (高能所)
-
10
Wrap-upSpeaker: Jianbei Liu (University of Science and Technology of China)
-
6
- 11
-
12
MinutesSpeakers: Fangyi Guo, Dr Yong Liu (Institute of High Energy Physics)
- Electronics by Jinfan
- Collect requirements as inputs: e.g. data throughput -> a list of specs
- To formulate Common requirements: e.g. waveform sampling (vs. data transmission speed)
- Mechanics by Quan, Shaojing
- Decided and implemented
- Barrel length: 5.9m -> for comparison of all calorimeter options
- ECAL: 28 R-Phi segments
- ECAL+HCAL: both inside magnet
- ECAL+HCAL: endcaps encompass barrel
- Decided but to be updated/implemented
- HCAL depth update: 1.08m -> 1.30m (to be confirmed by HCAL)
- To be decided
- HCAL: ? R-Phi segments -> not discussed
- Decided and implemented
- Feedback on the TDR meeting arragment: Yong
- 1 hour is toooo tight for discussions esp. on mechanics at this busy stage (many things not fixed yet..)
- Option 1: extend this discussion to 1.5h ? -> This would affect TDR meeting at 10AM
- Option 2: arrange internal discussions before the weekly meeting. Concise reports on status. -> Need to arrange another meeting...
- Other better options?
- Electronics by Jinfan
-
1