1. IE browser is NOT supported anymore. Please use Chrome, Firefox or Edge instead.
2. If you are a new user, please register to get an IHEP SSO account through https://login.ihep.ac.cn/registlight.jsp Any questions, please email us at helpdesk@ihep.ac.cn or call 88236855.
3. If you need to create a conference in the "Conferences, Workshops and Events" zone, please email us at helpdesk@ihep.ac.cn.
4. The max file size allowed for upload is 100 Mb.
21–26 May 2017
Beijing International Convention Center
Asia/Shanghai timezone

Results from Pilot Run for MEG II Positron Timing Counter

25 May 2017, 16:30
18m
Room 307 (Beijing International Convention Center)

Room 307

Beijing International Convention Center

No.8 Beichen Dong Road, Chaoyang District, Beijing P. R. China 100101
oral Photon detectors R4-Photon detectors(6)

Speaker

Mitsutaka Nakao (The University of Tokyo)

Description

The MEG II experiment at Paul Scherrer Institut in Switzerland will search for the lepton flavour violating muon decay, $\mu^+\to e^+\gamma$, with a sensitivity ($4\times10^{-14}$) improving the existing limit of an order of magnitude. The positron Timing Counter (pTC) is the subdetector dedicated to the measurement of the positron emission time. It is designed on the basis of a new approach to improve a positron ($e^+$) timing resolution by a factor of two compared to MEG. pTC is composed of 512 ultra-fast plastic scintillator with SiPM readouts. The mean hit multiplicity for signal $e^+$ is evaluated to be $\sim$ 9 and a high timing resolution of $\sim$ 35 ps is expected by averaging the signal time of multiple hit counters. To achieve the target resolution, an internal time calibration with a precision of 10 ps or better is required. We have developed two new methods for the calibration, which meet the requirement: Track-based calibration and Laser-based calibration. In 2016, We have finished construction of pTC and installed the first one-fourth of pTC into the MEG II experimental area to evaluate the performance using $\mu^+$ beam as a pilot run. We took data of $e^+$ from the dominant $\mu$ decay (Michel Decay, $\mu^+\to e^+\nu_e\overline{\nu}_{\mu}$) and applied both time calibration methods. The time offsets of each counter calculated independently from the two calibration methods were consistent and stable during the run within 6 ps. The systematic uncertainty between these methods was 39 ps, which is suppressed with $\frac{1}{\sqrt{N}}$ using multiple hits (N: number of hit counters). The overall timing resolution weighted with a distribution of the number of hit counters for signal $e^+$ of 38 ps was achieved in this pilot run. The prospects towards MEG II physics run are also discussed.

Primary author

Mitsutaka Nakao (The University of Tokyo)

Co-authors

Dr Alexander Mtchedlishvili (Paul Scherrer Institut) Antonio DE BARI (INFN Pavia) Dr Donato Nicolo (INFN Pisa) Prof. Flavio Gatti (University and INFN of Genova) Gianluigi Boca (INFN Pavia) Dr Luca Galli (INFN Pisa) Marcello Simonetta (INFN Pavia) Marco Francesconi (INFN Pisa) Mr Masashi Usami (The University of Tokyo) Massimo Rossella (INFN Pavia) Dr Matteo De Gerone (INFN Genova) Michele Biasotti (INFN Genova) Ms Miki Nishimura (The University of Tokyo) Dr Paolo walter Cattaneo (INFN Pavia) Dr Stefan Ritt (Paul Scherrer Institut) Prof. Wataru Ootani (ICEPP, The University of Tokyo) Dr Yusuke Uchiyama (ICEPP, The University of Tokyo)

Presentation materials