MDI:
Yifang:
- Firstly discuss the background estimate, this is the key points, then talk about the interaction region design.
- Use pointers to indicate, ensuring that what you say corresponds to what is being shown.
- Change the title to “beam background and MDI”
Manqi: The quantification of the background does not reflect in the results.
Tracker:
Yifang:
- Put the result of COFFEE-2 chip.
- Jianchun: already have many results, put 3-4 pages
- Put more ITk strip testing result, balance with other options
- Ignore internal details, like mechanics details
- Need to have comparison between strip and pixel
Jianchun: put one page for DC LGAD
TPC:
Minghsui: P4 remove the table, only mention 3%
ECAL:
Manqi: Suggest to put performance results in previous pages
HCAL:
- make sure simulation results shown in ECAL and HCAL talks using same calorimeter in simulation
- prepare one backup slides to prove why HCAL is 6 lamda, which related to cost
- prepare one backup slides to explain how 6% come from
- Prepare slides for cost estimation
Muon:
Yifang:
- reduce to 25 pages
- Electronics design should be finalized before review
Magnet:
- Jianchun: don’t list all chapters
- Yifang: P14 muon detector assembly should be unified, no dead zone, but need to consider impact of leakage issue
Electronics:
Yifang:
- remove P7
- GBTx: indicate that we are willing to cooperate with CERN. If it’s not woked, we are also ready for developing by ourselves
TDAQ:
Yifang: too many options, suggests to remove full software option
Software:
Yifang:
- should emphasis that our contribution is widely used by others
- need a schedule table, indicating what is missing and when to be finsihed
Mechanics:
Yifang:
- Create an animation of the installation sequence.
- P8 add a table, summarize deformation of xyz direction
Performance:
Yifang:
- Summary table missing new physics study: long-lived particle, missing momentum.
- P20 double check number with Yang Zhang
- P21 enlarge the table, remove column 2 and 3, add conclusion of physics improvement
- ECAL change to <2%, then update numbers in the table in page 21
Qi Yan:
- Suggest to introduce starting from detector indicator, then talk about physics indicators.